Hydraulic Operated 4″ Sliding Valve – 4″ Threaded Pipe x TTMA Flange

  • Hydraulically Operated
  • Spring Closed
  • TTMA or ANSI
  • Flange Drilling

The Betts Hydraulically Operated Sliding Valve meets requirements for an external self-closing stop valve. Valve does not contain a shear section. The cargo tank must protect the valve by providing suitable protection as specified in 49 CFR 178.345-8. The standard 316 stainless discs offer premium corrosion resistance and the adjustable packing nut allows for stem adjustments. The metal-to metal seal provides a positive seal for pressure or vacuum service, but is susceptible to wear and scratches. Fusible and Frangible Plugs may be installed in the hydraulic system for remote and heat actuated closing. Betts hydraulic pump part number HP18343 will operate one to three valves.

Parts List

Product Details

Assembly NumberFlange Dims.DimensionsWt.
SV46214***OD: 6.63" [168 mm]
BC: 5.88" [149 mm]
Holes: 8 - .44" [8 - 11 mm]
Thick.: .31" [7.9 mm]
A: 9.38" [238 mm]
B: 25.88" [657 mm]
C: N/A
D: 3.31" [84 mm]
E: 2.63" [67 mm]
72.5 lb. [32.9 kg]
* Sump flange and other combinations available upon request.

*** Last three letters of part number designate material of construction as shown below:

Example Assembly

SV46214SSM


(Hydraulic Operated 4″ Sliding Valve - 4" Threaded Pipe x TTMA Flange)
Material of Construction
MSM = Steel Body with 316 Stainless Stem & Gates
SSM = 316 Stainless Body, Stem & Gates
Flange bolt pattern per TTMA recommendations and grooved outlets per MIL-C-10387B.

** MAWP certified for new valves only. Seat/disc damage or wear may reduce sealable MAWP.

 

Repair Kits and Accessories


Teflon Accordion Packing

SV46261MS-4 (Actuator Assembly)

Additional Options

Use Suffix “008” for valve less actuator. A heat tube option is available by adding a suffix “J” to end of part number. (Heat tube MAWP = 150 psi)

Body MaterialValve MAWP**Min. Burst PressureTemp. Range
Steel or Stainless50 psi [3.4 bar]200 psi [13.8 bar]-40°F to 500°F [-40°C to 260°C]
NOTE: Valve should NEVER be heated with flame

Installation & Maintenance

See Bulletins and Parts List Page.

Engineering Bulletins

EB-04-98: Mounting Hydraulic Sliding Valve
Assembly to a Valve
EB-01-15: Important Notification for Gate/Sliding
Valves Used in Hot Service Application